CPSC 16 CFR 1201 PDF

CPSC 16 CFR 1201 PDF

CPSC 16CFR Category I Laminated Glass. Our tempered glass and laminated glass with a PVB interlayer or greater are. Category II safety rated . One of the most commonly recognizable code organizations is the Consumers Product Safety Commision (CPSC) that has set standard 16 CFR Category I . CFR Part The CPSC amended its Safety Standard for Architectural The principal differences between the CPSC’s 16 CFR standard and the ANSI.

Author: Taktilar Dakazahn
Country: Slovenia
Language: English (Spanish)
Genre: Art
Published (Last): 15 September 2016
Pages: 321
PDF File Size: 20.60 Mb
ePub File Size: 1.97 Mb
ISBN: 357-8-99708-229-6
Downloads: 42133
Price: Free* [*Free Regsitration Required]
Uploader: Femuro

There is too much required information to put it all on the permanent logo on the glass and still have the glass acceptable to owners and architects.

The typical process to produce tempered glass involves heating the glass to over 1, degrees F, then rapidly cooling to lock the glass surfaces in a state of compression and the core in a state of tension. Therefore, I see most manufacturers using a hybrid approach with 1021 information being distributed between the permanent logo, the shipping documentation and the fabricators website.

Does the glass then need to be labeled? This type of glass is intended for general glazing, and safety glazing such as sliding doors, storm doors, building entrances, bath and shower enclosures, interior partitions, and other uses requiring superior strength and safety properties. Fully tempered ClimaGuard glass is approximately four to five times stronger than annealed glass of the same thickness and configuration, residual surface compression must be over 10, PSI for 6mm, according to ASTM C Tempered glass cannot be cut or drilled after tempering, and any alterations, such as edge grinding, sand blasting or acid etching, can cause premature failure.

  JULIUS VIDA ANDROGENS ANABOLIC AGENTS PDF

Manufacturer’s name; mailing address and telephone number; month and year of manufacture; city and state where manufactured; safety standard; identification of the product by a “unique identifier;” custodian of testing records’ name, e-mail fpsc, mailing address cffr telephone number; date and place where the product was tested; and the third-party test laboratory’s name, mailing address and telephone number.

No reproduction, in print, electronic or any form without the expressed written permission of Key Communications Inc. They then will provide a statement on shipping documents that 1 certified 11201 meet the regulation, 2 addresses the date of manufacture, 3 identified the product, and 4 references a website where the remainder of the information may be obtained. Kent says it’s his understanding that the regulations apply, in effect, during the shipping period or process.

John Kent, administrator for the Safety Glazing Certification Council SGCCsays every manufacturer or importer of an architectural glazing material that is subject to 16 CFR Part will be required to comply with these new regulations, and this will certainly mean many fabricators will have a lot of questions.

Guardian Tempered Glass

For those companies that buy labeled glass and then have to cut it, the required information will still be available as Kent says it can appear on 1 a paper certificate, 2 the actual product label, or 3 by reference to a website, or some combination of these. All measurements taken from center-of-glass cfe. They may add ‘date of manufacture’ to the label if that is viable. Category I is for glass products with an area not 101 than 9 square feet and must endure a lb.

Compliance with a new set of U. For example, what happens if a fabricator has to remove and reinstall the same piece of glass?

  KANJI EIGOBAN PDF

AGC Glass Europe

Guardian Residential Glass Innovation. Learn About Window Glass.

To pass this standard, there must be a no fracture, or b if the glass fractures, the ten largest glass particles must weigh no more than 10 square inches of the original glass tested. To pass the standard, there must be a no fracture, or b if the glass fractures, the ten largest glass particles must weigh no more than 10 square inches of the original glass tested.

When broken, it will break into many relatively small fragments, which are less likely to cause serious injury.

Under these new regulations, manufacturer certifications of compliance with CPSC 16 CFR the federal safety standard for architectural glazing materials-must include the cfg Need more info and analysis about the issues? According to Kim Mann, general counsel for the Glass Association of North America, the CPSC has made it clear “that its first priority will not be policing certification and labeling requirements,” but, rather, dfr to ensure these consumer products meet the safety requirements in these standards.

Kent adds, “I believe most people will continue to label as they have in the past.

Some in the industry say these changes are not likely to have a huge impact on the way glass fabricators have already been doing business.